Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
CJEM ; 26(1): 23-30, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37976027

RESUMEN

OBJECTIVES: Bystander-applied Automated External Defibrillators (AED) improve outcomes for out-of-hospital cardiac arrest. AED placement is often driven by private enterprise or non-for-profit agencies, which may result in inequitable access. We sought to compare AED availability between four regions in British Columbia (BC). METHODS: We identified AEDs (confirmed to be operational) and emergency medical system (EMS)-treated out-of-hospital cardiac arrests (OHCA) from provincial registries. We compared AED availability between BC's four most populous regions. The primary outcome was the total regional weekly accessible AED-hours per 100,000 population. We also examined: AEDs per 100,000 population and per km2, the ratio of AEDs to OHCA, and the distance from each OHCA to the closest AED. RESULTS: From provincial registries, we included 879 AEDs from BC's four most populous regions, where 9333 EMS-treated OHCA occurred over a 5-year period. The most common AED location types were stores, public community centres, and office buildings. Ten percent of AEDs were accessible for all hours. Weekly accessible AED-hours/100,000 population in the four regions were: 3845, 1734, 1594, and 1299. AEDs/100,000 population ranged from 22 to 48, and AEDs/km2 ranged from 0.0048 to 0.20. The number of OHCAs per AED per year ranged from 1.1 to 2.8. The median OHCA-to-closest AED distance ranged from 503 (IQR 244, 947) to 925 (IQR 455, 1501) metres. The regional mean accessibility of individual AEDs ranged between 59 and 79 h per week. CONCLUSION: BC's four most populous regions demonstrate substantial variability in AED accessibility. Further benefit could be derived from AEDs if placed in locations accessible all hours. Our data may encourage community planning efforts to use data-based strategies to systematically place AEDs in optimal locations with strategies to maximize accessibility.


ABSTRAIT: OBJECTIFS: Les défibrillateurs externes automatisés (DEA) appliqués par les témoins améliorent les résultats en cas d'arrêt cardiaque hors hôpital. Le placement des DEA est souvent dirigé par une entreprise privée ou des organismes sans but lucratif, ce qui peut entraîner un accès inéquitable. Nous avons cherché à comparer la disponibilité des DEA entre quatre régions de la Colombie-Britannique. MéTHODES: Nous avons identifié les DEA (dont la mise en service a été confirmée) et les SMU (système médical d'urgence) traités par arrêt cardiaque hors hôpital (AHC) dans les registres provinciaux. Nous avons comparé la disponibilité des DEA entre les quatre régions les plus peuplées de la Colombie-Britannique. Le résultat principal était le nombre total d'heures de DEA accessibles hebdomadaires par région pour 100000 habitants. Nous avons également examiné : les DEA par 100000 habitants et par km2, le rapport entre les DEA et l'AHCA, et la distance entre chaque AHCA et le DEA le plus proche. RéSULTATS: À partir des registres provinciaux, nous avons inclus 879 DEA des quatre régions les plus peuplées de la Colombie-Britannique, où 9333 OHCA traités par les SMU se sont produits sur une période de 5 ans. Les types de DEA les plus courants étaient les magasins, les centres communautaires publics et les immeubles de bureaux. Dix pour cent des DEA étaient accessibles toutes les heures. La population hebdomadaire accessible en heures AED/100000 habitants dans les quatre régions était de 3845, 1734, 1594 et 1299. Le nombre de DEA/100 000 habitants variait de 22 à 48, et le nombre de DEA/km2 variait de 0,018 à 0,018. Le nombre de CASO par DEA par année variait de 1,1 à 2,8. La distance médiane entre le DEA OHCA et le DEA le plus proche variait de 503 mètres (IQR 244, 947) à 925 mètres (IQR 455, 1501). L'accessibilité moyenne régionale des DEA individuels variait entre 59 et 79 heures par semaine. CONCLUSION: Les quatre régions les plus populeuses de la Colombie-Britannique présentent une variabilité importante de l'accessibilité aux DEA. D'autres avantages pourraient découler des DEA s'ils sont placés dans des endroits accessibles toutes les heures. Nos données peuvent encourager les efforts de planification communautaire à utiliser des stratégies fondées sur les données pour placer systématiquement les DEA dans des endroits optimaux avec des stratégies pour maximiser l'accessibilité.


Asunto(s)
Reanimación Cardiopulmonar , Servicios Médicos de Urgencia , Paro Cardíaco Extrahospitalario , Humanos , Colombia Británica/epidemiología , Desfibriladores , Cardioversión Eléctrica , Paro Cardíaco Extrahospitalario/epidemiología , Paro Cardíaco Extrahospitalario/terapia
2.
Can J Cardiol ; 40(4): 500-523, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37820870

RESUMEN

Cardiovascular conditions are among the most frequent causes of impairment to drive, because they might induce unpredictable mental state alterations via diverse mechanisms like myocardial ischemia, cardiac arrhythmias, and vascular dysfunction. Accordingly, health professionals are often asked to assess patients' fitness to drive (FTD). The Canadian Cardiovascular Society previously published FTD guidelines in 2003-2004; herein, we present updated FTD guidelines. Because there are no randomized trials on FTD, observational studies were used to estimate the risk of driving impairment in each situation, and recommendations made on the basis of Canadian Cardiovascular Society Risk of Harm formula. More restrictive recommendations were made for commercial drivers, who spend longer average times behind the wheel, use larger vehicles, and might transport a larger number of passengers. We provide guidance for individuals with: (1) active coronary artery disease; (2) various forms of valvular heart disease; (3) heart failure, heart transplant, and left ventricular assist device situations; (4) arrhythmia syndromes; (5) implantable devices; (6) syncope history; and (7) congenital heart disease. We suggest appropriate waiting times after cardiac interventions or acute illnesses before driving resumption. When short-term driving cessation is recommended, recommendations are on the basis of expert consensus rather than the Risk of Harm formula because risk elevation is expected to be transient. These recommendations, although not a substitute for clinical judgement or governmental regulations, provide specialists, primary care providers, and allied health professionals with a comprehensive list of a wide range of cardiac conditions, with guidance provided on the basis of the level of risk of impairment, along with recommendations about ability to drive and the suggested duration of restrictions.


Asunto(s)
Sistema Cardiovascular , Enfermedad de la Arteria Coronaria , Demencia Frontotemporal , Isquemia Miocárdica , Humanos , Canadá/epidemiología , Arritmias Cardíacas/terapia
4.
Int J Cardiol ; 385: 17-21, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37257511

RESUMEN

BACKGROUND: Adults with congenital heart disease (ACHD) experience a high prevalence of atrial arrhythmia (AA) and thromboembolic cerebrovascular complications. However, data on AA and associated long-term outcomes are limited in ACHD patients with coarctation of the aorta (CoA). OBJECTIVES: This study aimed to characterize the prevalence and risk factors for AA and thromboembolic complications in adults with CoA. METHODS: We conducted a retrospective cohort study in a tertiary ACHD care center and included consecutive CoA patients older than 18 years old with more than one year of follow-up. RESULTS: Two hundred seventy patients with CoA were followed for 7.2 ± 3.95 years. The mean age was 35.3 ± 11.1 and 55.2% were male. Patients had a mean of 2.1 ± 1.8 cardiovascular surgical or transcatheter procedures. Thirty-five patients (13%) had AA. Ten subjects (3.8%) had a thromboembolic cerebrovascular event, of which four (1.4%) had AA. In univariate analysis, age (p = 0.005) and total intracardiac interventions (p = 0.007) were associated with the presence of AA. Age (p = 0.021), history of heart failure (p = 0.022), and dyslipidemia (p = 0.019) were associated with thromboembolism. In multivariate analysis, age (p < 0.001) and intracardiac interventions (p = 0.007) were associated with AA. CONCLUSIONS: The rate of AA is higher in adults with CoA than in the general population but lower than in other ACHD. Increasing age and intracardiac interventions were associated with AA. The rate of thromboembolic events was low. Some traditional risk factors for stroke may apply. Larger studies are needed to validate predictors for stroke in this population.


Asunto(s)
Coartación Aórtica , Cardiopatías Congénitas , Accidente Cerebrovascular , Tromboembolia , Humanos , Adulto , Masculino , Adulto Joven , Persona de Mediana Edad , Adolescente , Femenino , Estudios Retrospectivos , Cardiopatías Congénitas/epidemiología , Accidente Cerebrovascular/complicaciones , Tromboembolia/epidemiología
5.
Heart Fail Rev ; 28(2): 379-386, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36781809

RESUMEN

Cardiac conduction system pacing provides physiological ventricular activation by directly stimulating the conduction system. This review describes the two types of conduction system pacing: His bundle pacing (HBP) and left bundle area pacing (LBAP). The most significant advantage of HB pacing is that it can provide a regular, narrow QRS; however, the disadvantages are challenging implantation and a high risk of re-intervention due to lead dislodgement and the development of high pacing threshold. LBAP provides optimum physiological activation of the left ventricle by engaging the left bundle/fascicular fibers. LBAP is more physiological than traditional RV apical pacing and could be an attractive alternative to conventional cardiac resynchronization therapy (CRT). The advantages of LBAP are a relatively more straightforward implantation technique than HBP, better lead stability and pacing thresholds. HBP and LBAP are more physiological than right ventricular pacing and may be used instead of conventional pacemakers. Both HBP and LBBP are being investigated as alternatives to conventional CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Fascículo Atrioventricular , Electrocardiografía/métodos , Resultado del Tratamiento , Sistema de Conducción Cardíaco , Terapia de Resincronización Cardíaca/métodos , Estimulación Cardíaca Artificial/métodos
6.
Eur J Cardiovasc Nurs ; 22(8): 780-785, 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-36705579

RESUMEN

AIMS: Hypertrophic cardiomyopathy (HCM) is the most common inherited heart disease. Insertable cardiac monitors (ICMs) are increasingly used in this population to provide closer monitoring, with the potential for notification systems. However, little is known regarding the psychological impact this information may have on patients. The Abbott Confirm Rx™ ICM has the capability of connecting to the patient's smartphone to enable active participation in their care, as well as two-way communication between the patient and their care providers. This study aimed to explore individuals' experiences of having a smartphone-enabled ICM to monitor for arrhythmias in HCM. METHODS AND RESULTS: Semi-structured interviews were conducted with 10 participants. Utilizing a grounded theory approach, the interview guide was modified based on emerging themes throughout the study. Reflexive thematic analysis was applied to categorize interview data into codes and overacting themes, with each interview independently coded by two study members. Analysis revealed three key themes: (i) psychological impact, (ii) educational needs, and (iii) technology expectations. Participants reported that receiving feedback from ICM transmissions resulted in improved symptom clarity, providing reassurance, and aiding implantable cardioverter defibrillator decision-making. Some participants reported uncertainty regarding when to send manual transmissions. Lastly, participants reported the app interface did not meet expectations with regard to the amount of data available for patients. CONCLUSION: Overall, utilizing a smartphone app to facilitate two-way communication of ICM transmissions was well accepted. Future directions include addressing gaps in educational needs and improvements in the patient interface with increased access to data.


Asunto(s)
Cardiomiopatía Hipertrófica , Desfibriladores Implantables , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Electrocardiografía , Desfibriladores Implantables/psicología , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/terapia , Cardiomiopatía Hipertrófica/psicología , Evaluación del Resultado de la Atención al Paciente
7.
Pacing Clin Electrophysiol ; 46(2): 138-143, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36514201

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) using radiofrequency catheter ablation is a widely accepted therapy for drug-refractory atrial fibrillation patients. Elimination of the negative component of the local unipolar electrogram (UEGM) during PVI is a marker of transmural lesion formation. The ablation index (AI) can predict the quality of ablation lesion. Combining these two parameters could make PVI safer and efficient. The purpose of this pilot study was to examine the correlation between UEGM modification characteristics of the different target areas of left atrium and the associated AI values during PVI. METHODS: We analyzed 10 patients who underwent PVI using radiofrequency energy. The local electrophysiological properties and ablation parameters of 15 designated areas of interest in the left atria targeted by radiofrequency catheter ablation were collected. RESULTS: Out of the 10 patients, six were men (mean age 66 years) and 80% had paroxysmal AF. The mean time to achieve the UEGM modification in the posterior wall was shorter than that of the anterior wall (8.9 seconds vs. 11.1 s, respectively). The UEGM modification for every lesion was achieved at significantly lower AI values than conventional AIs (p < .001). CONCLUSION: During PVI, the AIs deduced according to the local UEGM modification are markedly shorter than those generally recommended AIs in contemporary practice. This indicates that conventionally recommended AIs could be safely reduced while ensuring the efficacy and quality of radiofrequency ablation during PVI. This approach would probably reduce to risk of collateral thermal injuries.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Masculino , Humanos , Anciano , Femenino , Proyectos Piloto , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Atrios Cardíacos , Resultado del Tratamiento , Recurrencia
8.
Europace ; 25(2): 400-407, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36164922

RESUMEN

AIMS: Same-day discharge is increasingly common after catheter ablation for atrial fibrillation (AF). However, the impact of same-day discharge on healthcare utilization after ablation and whether this differs by ablation modality remains uncertain. We examined the safety, efficacy, and subsequent healthcare utilization of a same-day discharge protocol for AF ablation, including radiofrequency (RF) and cryoballoon ablation, in a contemporary cohort. METHODS AND RESULTS: All consecutive patients for whom full healthcare utilization data were available at two centres and who underwent AF ablation from 2018 to 2019 were included. Same-day discharge was the default strategy for all patients. The efficacy and safety outcomes were proportions of same-day discharge and readmission/emergency room (ER) visits, and post-discharge complications, respectively. Of the 421 patients who underwent AF ablation (mean 63.3 ± 10.2 years, 33% female), 90.5% (381/421) achieved same-day discharge with no difference between RF and cryoballoon ablation (89.8 vs. 95.1%, adjusted P = 0.327). Readmission ≤30 days occurred in 4.8%, with ER visits ≤30 days seen in 26.1% with no difference between ablation modalities (P = 0.634). Patients admitted overnight were more likely to present to the ER (40.0 vs. 24.7% with same-day discharge, P = 0.036). The overall post-discharge complication rate was low at 4/421 (1.0%), with no difference between ablation modality (P = 0.324) and admission/same-day discharge (P = 0.485). CONCLUSION: Same-day discharge can be achieved in a majority of patients undergoing RF or cryoballoon ablation for AF. Healthcare utilization, particularly ER visits, remains high after AF ablation, regardless of ablation modality or same-day discharge.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Femenino , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Alta del Paciente , Cuidados Posteriores , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia , Venas Pulmonares/cirugía
9.
CJC Open ; 4(11): 946-958, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36444361

RESUMEN

An expanded role for cardiac implantable electronic devices (CIEDs) in recent decades reflects an aging population and broader indications for devices, including both primary prevention and management of dysrhythmias. CIED infection is one of the most important device-related complications and has a major impact on mortality, quality of life, healthcare utilization, and cost. Unfortunately, the investigation and management of CIED infection remain complex, often necessitating complete and timely removal of the device and leads in order to eradicate the infection. In addition, the translation of knowledge from an extensive literature to a disparate group of medical practitioners has often been inadequate. This review of CIED infection management highlights the significant advances made during the past decade, including diagnostic criteria, advanced imaging, and next-generation sequencing for culture-negative cases or those in which uncertainty remains. We also outline the role and indication for powered lead extraction, the process of antibiotic choice and treatment duration, considerations related to the timing and location for reimplantation, and preimplantation risk stratification and associated interventions to reduce the risk of CIED infection.


L'élargissement du rôle des dispositifs électroniques cardiaques implantables (DECI) au cours des dernières décennies reflète le vieillissement de la population et les indications plus vastes des dispositifs, notamment dans la prévention primaire et la prise en charge des dysrythmies. Les infections liées aux DECI sont l'une des plus importantes complications liées aux dispositifs et ont des conséquences majeures sur la mortalité, la qualité de vie, l'utilisation et les coûts des soins de santé. Malheureusement, le dépistage et la prise en charge des infections liées aux DECI demeurent complexes et nécessitent souvent le retrait complet et rapide du dispositif et des sondes en vue d'éradiquer l'infection. De plus, l'application des connaissances issues d'une vaste littérature à un groupe disparate de médecins praticiens a souvent été inadéquate. La présente revue sur la prise en charge des infections liées aux DECI illustre les avancées importantes réalisées au cours de la dernière décennie, notamment les critères diagnostiques, l'imagerie avancée et le séquençage de prochaine génération des cas à culture négative ou de ceux pour lesquels des incertitudes demeurent. Nous avons aussi décrit le rôle et les indications d'extraction des sondes fonctionnelles, le processus du choix des antibiotiques et de la durée du traitement, les considérations relatives au moment et au lieu de la réimplantation, et la stratification du risque en préimplantation et les interventions associées afin de réduire le risque d'infections liées aux DECI.

10.
JACC Clin Electrophysiol ; 8(9): 1122-1132, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36137717

RESUMEN

BACKGROUND: The role of cardiac magnetic resonance (CMR) in the evaluation and management of patients with frequent premature ventricular complexes (PVCs) of unknown etiology remains unclear. OBJECTIVES: This study evaluated the prevalence and prognostic significance of myocardial abnormalities detected with CMR among patients with frequent PVCs and no known structural heart disease. METHODS: This prospective cohort study included consecutive patients with frequent PVCs and a negative initial diagnostic work-up who underwent CMR with late gadolinium enhancement imaging. The clinical outcome was a composite of mortality, ventricular fibrillation, sustained ventricular tachycardia, or reduction in left ventricular ejection fraction of ≥10%. RESULTS: A total of 255 patients were included, of whom 35 (13.7%) had evidence of myocardial abnormality on CMR. Age ≥60 years (odds ratio [OR]: 6.96; 95% CI: 1.30-37.18), multifocal PVCs (OR: 10.90; 95% CI: 3.21-36.97), and non-outflow tract left ventricular PVC origin (OR: 3.00; 95% CI: 1.00-8.95) were independently associated with the presence of a myocardial abnormality on CMR. After a median follow-up of 36 months, the composite outcome occurred in 15 (5.9%) patients. The presence of a myocardial abnormality on CMR was independently associated with the composite outcome (HR: 4.35; 95% CI: 1.34-14.15; P = 0.014). CONCLUSIONS: One in 7 patients with frequent PVCs with no known structural heart disease had myocardial abnormality detected on CMR, and these abnormalities were associated with adverse clinical outcomes. These findings highlight the important role of CMR in the evaluation of patients with frequent PVCs.


Asunto(s)
Función Ventricular Izquierda , Complejos Prematuros Ventriculares , Humanos , Persona de Mediana Edad , Medios de Contraste , Gadolinio , Espectroscopía de Resonancia Magnética , Estudios Prospectivos , Volumen Sistólico , Complejos Prematuros Ventriculares/diagnóstico
12.
J Am Heart Assoc ; 11(9): e023516, 2022 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-35470701

RESUMEN

Background This study sought to better understand the experiences of adults with congenital heart disease throughout the pandemic. Objectives were to determine (1) psychological distress before and throughout the pandemic; (2) changes in day-to-day functioning; and (3) the percentage of adults with congenital heart disease who experienced COVID-19 related symptoms, underwent testing, and tested positive. Methods and Results This was a cross-sectional study paired with retrospective chart review. A web-based survey was distributed to patients between December 2020 and January 2021. Patients reported on psychological distress across 5 categories (Screening Tool for Psychological Distress; depression, anxiety, stress, anger, and lack of social support), whether they experienced symptoms of COVID-19 and/or sought testing, and changes to their work and social behavior. Five hundred seventy-nine survey responses were received, of which 555 were linked to clinical data. Patients were aged 45±15 years. The proportion of patients reporting above-threshold values for all Screening Tool for Psychological Distress items significantly increased during the early pandemic compared with before the pandemic. Stress returned to baseline in December 2020/January 2021, whereas all others remained elevated. Psychological distress decreased with age, and women reported persistently elevated stress and anxiety compared with men during the pandemic. A consistent trend was not observed with regard to American College of Cardiology/American Heart Association anatomic and physiologic classification. Fifty (9%) patients lost employment because of a COVID-19-related reason. COVID-19 symptoms were reported by 145 (25%) patients, 182 (31%) sought testing, and 10 (2%) tested positive. Conclusions A substantial proportion of adults with congenital heart disease reported clinically significant psychological distress during the pandemic.


Asunto(s)
COVID-19 , Cardiopatías Congénitas , Distrés Psicológico , Adulto , COVID-19/epidemiología , Estudios Transversales , Depresión/psicología , Femenino , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/epidemiología , Humanos , Masculino , Pandemias , Estudios Retrospectivos , Estrés Psicológico/diagnóstico , Estrés Psicológico/epidemiología , Estados Unidos
13.
Resuscitation ; 172: 194-200, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35031391

RESUMEN

BACKGROUND: The optimal locations and cost-effectiveness of placing automated external defibrillators (AEDs) for out-of-hospital cardiac arrest (OHCAs) in urban residential neighbourhoods are unclear. METHODS: We used prospectively collected data from 2016 to 2018 from the British Columbia OHCA Registry to examine the utilization and cost-effectiveness of hypothetical AED deployment in municipalities with a population of over 100 000. We geo-plotted OHCA events using seven hypothetical deployment models where AEDs were placed at the exteriors of public schools and community centers and fetched by bystanders. We calculated the "radius of effectiveness" around each AED within which it could be retrieved and applied to an individual prior to EMS arrival, comparing automobile and pedestrian-based retrieval modes. For each deployment model, we estimated the number of OHCAs within the "radius of effectiveness". RESULTS: We included 4017 OHCAs from ten urban municipalities. The estimated radius of effectiveness around each AED was 625 m for automobile and 240 m for pedestrian retrieval. With AEDs placed outside each school and community center, 2567 (64%) and 605 (15%) of OHCAs fell within the radii of effectiveness for automobile and pedestrian retrieval, respectively. For each AED, there was an average of 1.20-2.66 and 0.25-0.61 in-range OHCAs per year for automobile retrieval and pedestrian retrieval, respectively, depending on the deployment model. All of our proposed surpassed the cost-effectiveness threshold of 0.125 OHCA/AED/year provided > 5.3-11.6% in-range AEDs were brought-to-scene. CONCLUSIONS: The systematic deployment of AEDs at schools and community centers in urban neighbourhoods may result in increased application and be a cost-effective public health intervention.


Asunto(s)
Reanimación Cardiopulmonar , Servicios Médicos de Urgencia , Paro Cardíaco Extrahospitalario , Colombia Británica/epidemiología , Ciudades , Análisis Costo-Beneficio , Desfibriladores , Humanos , Paro Cardíaco Extrahospitalario/terapia , Instituciones Académicas
14.
Circulation ; 145(10): 742-753, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-34913361

RESUMEN

BACKGROUND: Regulatory authorities of most industrialized countries recommend 6 months of private driving restriction after implantation of a secondary prevention implantable cardioverter-defibrillator (ICD). These driving restrictions result in significant inconvenience and social implications. This study aimed to assess the incidence rate of appropriate device therapies in contemporary recipients of a secondary prevention ICD. METHODS: This retrospective study at 3 Canadian tertiary care centers enrolled consecutive patients with new secondary prevention ICD implants between 2016 and 2020. RESULTS: For a median of 760 days (324, 1190 days), 721 patients were followed up. The risk of recurrent ventricular arrhythmia was highest during the first 3 months after device insertion (34.4%) and decreased over time (10.6% between 3 and 6 months, 11.7% between 6 and 12 months). The corresponding incidence rate per 100 patient-days was 0.48 (95% CI, 0.35-0.64) at 90 days, 0.28 (95% CI, 0.17-0.45) at 180 days, and 0.21 (95% CI, 0.13-0.33) between 181 and 365 days after ICD insertion (P<0.001). The cumulative incidence of arrhythmic syncope resulting in sudden cardiac incapacitation was 1.8% within the first 90 days and subsequently dropped to 0.4% between 91 and 180 days (P<0.001) after ICD insertion. CONCLUSIONS: The incidence rate of appropriate therapies resulting in sudden cardiac incapacitation in contemporary recipients of a secondary prevention ICD is much lower than previously reported and declines significantly after the first 3 months. Lowering driving restrictions to 3 months after the index cardiac event seems safe, and revision of existing guidelines should be considered in countries still adhering to a 6-month period. Existing restrictions for private driving after implantation of a secondary prevention ICD should be reconsidered.


Asunto(s)
Desfibriladores Implantables , Canadá , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Humanos , Prevención Primaria/métodos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
15.
PEC Innov ; 1: 100104, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37213750

RESUMEN

Objective: To evaluate a pilot education program designed to improve patients' experience of living well with an implantable cardioverter-defibrillator (ICD). Methods: Patient Partners with previously implanted ICD and clinicians collaboratively performed monthly education sessions for potential and recent ICD recipients. Curriculum development was informed by current evidence of ICD patients' unique educational needs; delivery format transitioned to a virtual platform following the onset of COVID-19. Participants' experience was evaluated using a tailored questionnaire to explore preliminary insights. Results: 126 participants (median age: 62 years; women: 30%) attended 24 sessions. In-person participants (n = 62, 49.2%) reported sessions as helpful (n = 56, 94%) with regards to format and Patient Partner interactions. Virtual participants 64 (50.8%) completed an electronic survey (n = 27, 45%); reporting sufficient information for most topics with the exception of potential psychological effects of ICD implantation. Patient Partners as collaborative session leaders was perceived to be very helpful (n = 22, 82%) or somewhat helpful (n = 5, 18%). Conclusion: This novel educational partnership met the learning needs of patients at the vulnerable time of new cardiac device implantation of both in-person and virtual formats. Innovation: The inclusion of Patient Partners in co-led cardiac education informs novel approach to care that may improve patients' experiences of living well with complex technology.

16.
J Arrhythm ; 37(6): 1546-1554, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34887960

RESUMEN

BACKGROUND: Adults with repaired Tetralogy of Fallot (rTOF) comprise one of the largest cohorts among adults with congenital heart disease (ACHD). These patients have a higher burden of atrial arrhythmias (AA), leading to increased adverse events, including stroke and transient ischemic attack (TIA). However, the data on factors associated with stroke/TIA in rTOF are limited, and classic risk factors may not apply. We studied event rates and associated factors for thromboembolism in a rTOF cohort. METHODS: Retrospective cohort study of all adult patients age >18 years with rTOF followed at a single ACHD tertiary care center. AA of interest were atrial fibrillation (AF) and atrial flutter (AFL). RESULTS: Data from 260 patients were identified, mean age 37.6 SD 13.3 years, followed over 5108 patient-years (mean 16.6 SD 8.2 years). 43 patients had AF and/or AFL, and 30 patients had thromboembolic events, of which 19 patients had stroke/TIA. The event rate for any thromboembolism was 3.39 per 100 patient-years follow-up in patients with AA, compared to 1.80 in patients without (P = .07). In univariate analysis, older age and diabetes were associated with thromboembolic events. In multivariate analysis, only older age was associated with thromboembolic events. CONCLUSIONS: In our relatively young cohort of adults with rTOF, there was a high prevalence of AA, associated with nearly double the rate of thromboembolic events compared to patients without AA. Older age alone is independently associated with thromboembolic events. Further studies into assessment of silent AA are required, and routine assessments should be considered at an earlier age.

18.
J Cardiovasc Electrophysiol ; 32(8): 2246-2253, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34216056

RESUMEN

INTRODUCTION: The relative effectiveness of medical therapy compared with a conservative approach of monitoring in patients with idiopathic frequent premature ventricular complexes (PVCs) is uncertain. We evaluated the effectiveness of medical versus conservative therapy for frequent PVCs. METHODS: Patients with frequent PVCs (≥5%) were prospectively enrolled in this cohort study between 2016 and 2020. In patients with normal cardiac function and no structural heart disease, those receiving medical therapy were compared with controls without therapy. Patients were followed longitudinally for change in PVC burden and with serial echocardiography. RESULTS: Overall, 120 patients met inclusion criteria (mean: 56.5 ± 14.6 years, 54.2% female) with 53 on beta-blockers or calcium channel blockers (BBs/CCBs), 27 on Class I or III antiarrhythmic drugs (AADs), and 40 patients treated conservatively. Median initial PVC burden ranged from 15.5% to 20.6%. The median relative reduction of PVCs was 32.7%, 30.5%, and 81.3%, in the conservative therapy, BBs/CCBs, and AADs cohorts, respectively. AADs had greater PVC reduction compared with BBs/CCBs (p = 0.017) and conservative therapy (p = 0.045). PVC reduction to <1% was comparable across groups at 35.0%, 17.0%, 33.3%, respectively. Four patients (4/120, 3.3%) developed left ventricular dysfunction. Rates of adverse drug reactions and medication discontinuation were similar between groups, with no serious adverse events noted. CONCLUSION: In patients with idiopathic frequent PVCs, BB, and CCB have limited effectiveness in PVC reduction. Class I and III AADs have superior effectiveness for medical therapy in symptomatic patients, but only achieved complete PVC resolution suppression in one-third of patients.


Asunto(s)
Disfunción Ventricular Izquierda , Complejos Prematuros Ventriculares , Antiarrítmicos/efectos adversos , Estudios de Cohortes , Ecocardiografía , Femenino , Humanos , Masculino , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/tratamiento farmacológico
20.
Can J Cardiol ; 37(10): 1648-1650, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34010633

RESUMEN

The Medical Assistance in Dying (MAiD) program has been steadily expanding in Canada, and is expected to continue to do so. There are a substantial number of Canadians with pacemakers and defibrillators, many of whom are potential MAiD recipients. There is a need for review and reflection of standardisation of cardiac device management in MAiD patients, not only because of ethical concerns, but also because of the complexity of management at end of life. This document examines the status and role of cardiac devices (pacemakers and intracardiac defibrillators) and their physiologic interactions and influences during the MAiD process, and provides recommendations for their management.


Asunto(s)
Enfermedades Cardiovasculares/terapia , Desfibriladores Implantables , Guías como Asunto , Asistencia Médica/organización & administración , Cuidado Terminal/normas , Enfermo Terminal , Canadá , Humanos , Cuidado Terminal/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...